We use cookies in order to guarantee the best possible service. If you continue browsing the site you consent to our cookie use.

Hioki-3169-20 CLAMP ON POWER HiTESTER

Demand Measurement up to 4 Circuits and Simultaneous Harmonics Analysis

Key Features and Functions

  • Simultaneously measure demand and harmonic waveforms that share the same voltage line over 4-circuits
  • Data can be saved onto a PC card
  • High-speed and continuous processing to measure individual waveforms
  • High-speed D/A output for analog graph recording (Model 3169-21)

Documents and Software:

Product Number:

Hioki-3169

Manufacturer:

Hioki

Quantity:

Total
Unit price
base price
Stock
Call or email for delivery time

Hioki portable power meters and analyzers are best in class power measuring instruments for measuring single to three-phase lines with a high degree of precision and accuracy. The 3169 is clamp on power meters designed to measure demand and harmonics, which are important for energy management, as well as basic electrical parameters such as voltage, current, power, power factor, and integrated power (watthours).

Basic specifications

  • Measurement line & number of circuits: Single-phase 2-wires (4 circuits), Single-phase 3-wires (2 circuits), Three-phases 3-wires (2 or 1 circuit), and Three-phases 4-wires (1 circuit) Note: 50 or 60 Hz, and that share the same voltage line
  • Measurement items: Voltage, Current, Active/ reactive/ apparent power, Active/ reactive power integration, Power factor, Frequency, Harmonic waveform value (up to 40th order)
  • Measurement range: [Voltage] 150.00 V to 600.00 V AC, 3 ranges, [Current] 500.00 mA to 5.0000 kA AC (depends on current sensor in use), [Power] 75.000 W to 900.00 kW (depends on combination of voltage, current range, and measurement line)
  • Basic accuracy: AC Voltage: ±0.2 % rdg. ±0.1 % f.s.
  • AC Current: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy
  • Active power: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy (at power factor = 1)
  • Clamp on sensor 9661: ±0.3 % rdg. ±0.01 % f.s. (different from each sensor models)
  • Measurement method: Digital sampling, PLL synchronization or 50/60 Hz fixed clock
  • Display refresh rate: 2 times /sec (except when a PC card accessing, or RS-232C communications)
  • Data save interval: Standard interval: 1 sec to 30 sec, 1 minute to 60 minutes, 13 selects
  • Fast interval: A single waveform, or 0.1, 0.2, or 0.5 sec (at instant value only)
  • Frequency characteristics: Fundamental waveforms up to the 50th order
Description
Additional Informations
Reviews
Query on the Item
Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha
Description
Reviews
Query on the Item

Hioki portable power meters and analyzers are best in class power measuring instruments for measuring single to three-phase lines with a high degree of precision and accuracy. The 3169 is clamp on power meters designed to measure demand and harmonics, which are important for energy management, as well as basic electrical parameters such as voltage, current, power, power factor, and integrated power (watthours).

Basic specifications

  • Measurement line & number of circuits: Single-phase 2-wires (4 circuits), Single-phase 3-wires (2 circuits), Three-phases 3-wires (2 or 1 circuit), and Three-phases 4-wires (1 circuit) Note: 50 or 60 Hz, and that share the same voltage line
  • Measurement items: Voltage, Current, Active/ reactive/ apparent power, Active/ reactive power integration, Power factor, Frequency, Harmonic waveform value (up to 40th order)
  • Measurement range: [Voltage] 150.00 V to 600.00 V AC, 3 ranges, [Current] 500.00 mA to 5.0000 kA AC (depends on current sensor in use), [Power] 75.000 W to 900.00 kW (depends on combination of voltage, current range, and measurement line)
  • Basic accuracy: AC Voltage: ±0.2 % rdg. ±0.1 % f.s.
  • AC Current: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy
  • Active power: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy (at power factor = 1)
  • Clamp on sensor 9661: ±0.3 % rdg. ±0.01 % f.s. (different from each sensor models)
  • Measurement method: Digital sampling, PLL synchronization or 50/60 Hz fixed clock
  • Display refresh rate: 2 times /sec (except when a PC card accessing, or RS-232C communications)
  • Data save interval: Standard interval: 1 sec to 30 sec, 1 minute to 60 minutes, 13 selects
  • Fast interval: A single waveform, or 0.1, 0.2, or 0.5 sec (at instant value only)
  • Frequency characteristics: Fundamental waveforms up to the 50th order
Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha