Hioki-DT4254 DIGITAL MULTIMETER

Digital Multimeter for Efficiently Maintaining Power Equipment, PV and Megasolar Devices

Key Features and Functions

  • The voltage measurement model, which is ideal for solar power system and power equipment management, measures up to 1700 V DC during open voltage inspections (DT4254)
  • Prevents accidents with clamp-on sensor-based current measurement (DT4254, DT4255)
  • Voltage detection function (DT4254, DT4255)
  • Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
  • Broad -25°C (-13°F) to 65°C (149°F) operating temperature range (DT4254, DT4255)
  • Dual display lets you check voltage and frequency simultaneously

Documents and Software:

Product Number:

Hioki-DT4254

Manufacturer:

Hioki

Quantity:

Total
Unit price
base price
Stock
Call or email for delivery time

The Hioki DT4200 Digital Multimeter Series consist of a complete lineup of 9 models ranging from professional to industrial to pocket meters, delivering a super fast response rate and safety features that take electrical testing to a higher level. The DT4254 is a voltage measurement only model designed for measuring photovoltaic modules and other high-voltage targets up to 1700 V DC

Accuracy guaranteed: 1 year, Accuracy guarantee period after adjustment made by Hioki: 1 year

Regarding DMM Accuracy: Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the brochure for detailed accuracy information. *1 Your instrument can be used to measure voltages in excess of 1000 V DC if and only if both of the following conditions are satisfied: 1. The circuit under measurement is isolated from the commercial power grid. 2. The circuit under measurement is isolated from ground.

  • DC Voltage range:
    • 600.0 mV to 1700 V (*1)
    • 5 ranges, Basic accuracy: ±0.3 % rdg. ±3 dgt.
  • AC Voltage range:
    • 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz
    • Basic accuracy 40 - 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)
  • AUTO AC/DCV: Yes
  • Resistance range: N/A
  • DC Current range: N/A
  • From 4 to 20mA Percentage conversion display: N/A
  • AC Current range (use with Clamp on probes): N/A
  • Temperature (thermocouples): N/A
  • Voltage detection: Hi: AC40 V to 600 V, Lo: AC80 V to 600 V
  • Capacitance range: N/A
  • Frequency range: 99.99 Hz to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage),
  • Basic accuracy: ±0.1 % rdg. ±1 dgt.
  • Continuity check: N/A
  • Diode test: N/A
  • Other functions: Filter function, display value hold, auto hold, MAX/MIN/Average value display, relative value display, auto-power save, USB communication (option)
  • Display: Main and Sub displays: 4-digits LCD, max. 6000 digits, bar graph
  • Display refresh rates: 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s)
  • Power supply: LR03 alkaline batteries ×4, Continuous use: 130 hours (backlight OFF)
  • Dimensions and mass:
    • 84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D,
    • 390 g (13.8 oz) (including batteries and holster)
  • Accessories: Test lead L9207-10 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4
Description
Additional Informations
Reviews
Query on the Item
Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha
Description
Reviews
Query on the Item

The Hioki DT4200 Digital Multimeter Series consist of a complete lineup of 9 models ranging from professional to industrial to pocket meters, delivering a super fast response rate and safety features that take electrical testing to a higher level. The DT4254 is a voltage measurement only model designed for measuring photovoltaic modules and other high-voltage targets up to 1700 V DC

Accuracy guaranteed: 1 year, Accuracy guarantee period after adjustment made by Hioki: 1 year

Regarding DMM Accuracy: Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the brochure for detailed accuracy information. *1 Your instrument can be used to measure voltages in excess of 1000 V DC if and only if both of the following conditions are satisfied: 1. The circuit under measurement is isolated from the commercial power grid. 2. The circuit under measurement is isolated from ground.

  • DC Voltage range:
    • 600.0 mV to 1700 V (*1)
    • 5 ranges, Basic accuracy: ±0.3 % rdg. ±3 dgt.
  • AC Voltage range:
    • 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz
    • Basic accuracy 40 - 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)
  • AUTO AC/DCV: Yes
  • Resistance range: N/A
  • DC Current range: N/A
  • From 4 to 20mA Percentage conversion display: N/A
  • AC Current range (use with Clamp on probes): N/A
  • Temperature (thermocouples): N/A
  • Voltage detection: Hi: AC40 V to 600 V, Lo: AC80 V to 600 V
  • Capacitance range: N/A
  • Frequency range: 99.99 Hz to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage),
  • Basic accuracy: ±0.1 % rdg. ±1 dgt.
  • Continuity check: N/A
  • Diode test: N/A
  • Other functions: Filter function, display value hold, auto hold, MAX/MIN/Average value display, relative value display, auto-power save, USB communication (option)
  • Display: Main and Sub displays: 4-digits LCD, max. 6000 digits, bar graph
  • Display refresh rates: 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s)
  • Power supply: LR03 alkaline batteries ×4, Continuous use: 130 hours (backlight OFF)
  • Dimensions and mass:
    • 84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D,
    • 390 g (13.8 oz) (including batteries and holster)
  • Accessories: Test lead L9207-10 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4