We use cookies in order to guarantee the best possible service. If you continue browsing the site you consent to our cookie use.

Hioki 3280-70F AC CLAMP METER SET (includes CT6280 sensor)

Rugged & Compact, Essential Equipment for Professional Electricians: Measure Current and Voltage with a Single Instrument

Key Features and Functions

  • Measure the fundamental waveform component using the average rectified method
  • Expanded -25°C to 65°C operating temperature range
  • Connect the CT6280 flexible sensor to measure up to 4199 A in thick or paired wires
  • Drop proof design withstands drop from a height of 1 meter

Documents and Software:

Price
 
kr 2.624*
* excluding VAT plus shipping

Product Number:

Hioki-3280-70F

Manufacturer:

Hioki

Quantity:

Total
Unit price
Base Product
Availability:
Typically on stock
On Stock. 1-2 weeks delivery

Hioki clamp meters are best-in-class measuring devices incorporating Hioki’ s expertise in current sensing technology. The 3280-10F is an average rectifying 1000A AC clamp meter that features a broad operating temperature range of -25°C to 65°C, thin and compact clamp core and optional flexible current sensor that you can attach to let you get into the tightest spots.

CAT IV 300 V (Current)
CAT III 600 V (Current)
CAT III 300 V (Voltage)

Using 3280 series AC clamp meters: Introduction to functionality and measurement methods

In addition to AC current measurement, these clamp meters provide voltage and resistance measurement as well as continuity check functionality.

Their compact size, low-profile design, and resistance to both rough handling and extreme temperatures make them essential tools for any electrician.

Basic specifications

Accuracy guaranteed: 1 year

AC Current range

41.99 to 1000 A, 3 ranges (50 Hz to 60 Hz, Average rectified),
Basic accuracy: ±1.5 % rdg. ±5 dgt.

DC Voltage range

419.9 mV to 600 V, 5 ranges, Basic accuracy: ±1.0 % rdg. ±3 dgt.

AC Voltage range

4.199 V to 600 V, 4 ranges
(45 to 500 Hz, Average rectified),
Basic accuracy: ±1.8 % rdg. ±7 dgt.

Crest factor

N/A

Resistance range

419.9 Ω to 41.99 MΩ, 6 ranges, Basic accuracy: ±2 % rdg. ±4 dgt.

Other functions

Continuity: Buzzer sounds at 50 Ω ±40 Ω or less, Data hold, Auto power save, Drop-proof from height of 1 meter

Display

LCD, max. 4199 dgt., Display refresh rate: 400 ms

Environmental protection

IP40 dustproof and waterproof (while in storage)

Power supply

Coin type lithium battery (CR2032) ×1, Continuous use 120 hours

Core jaw dia.

φ 33 mm (1.30 in)

Dimensions and mass

57 mm (2.24 in) W × 175 mm (6.89 in) H × 16 mm (0.63 in) D, 100 g (3.5 oz)

Included accessories

CARRYING CASE 9398 ×1, TEST LEAD L9208 ×1, Coin type lithium battery (CR2032) ×1, Instruction manual ×1

Description
Additional Informations
Reviews
Query on the Item
Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha
Description
Reviews
Query on the Item

Hioki clamp meters are best-in-class measuring devices incorporating Hioki’ s expertise in current sensing technology. The 3280-10F is an average rectifying 1000A AC clamp meter that features a broad operating temperature range of -25°C to 65°C, thin and compact clamp core and optional flexible current sensor that you can attach to let you get into the tightest spots.

CAT IV 300 V (Current)
CAT III 600 V (Current)
CAT III 300 V (Voltage)

Using 3280 series AC clamp meters: Introduction to functionality and measurement methods

In addition to AC current measurement, these clamp meters provide voltage and resistance measurement as well as continuity check functionality.

Their compact size, low-profile design, and resistance to both rough handling and extreme temperatures make them essential tools for any electrician.

Basic specifications

Accuracy guaranteed: 1 year

AC Current range

41.99 to 1000 A, 3 ranges (50 Hz to 60 Hz, Average rectified),
Basic accuracy: ±1.5 % rdg. ±5 dgt.

DC Voltage range

419.9 mV to 600 V, 5 ranges, Basic accuracy: ±1.0 % rdg. ±3 dgt.

AC Voltage range

4.199 V to 600 V, 4 ranges
(45 to 500 Hz, Average rectified),
Basic accuracy: ±1.8 % rdg. ±7 dgt.

Crest factor

N/A

Resistance range

419.9 Ω to 41.99 MΩ, 6 ranges, Basic accuracy: ±2 % rdg. ±4 dgt.

Other functions

Continuity: Buzzer sounds at 50 Ω ±40 Ω or less, Data hold, Auto power save, Drop-proof from height of 1 meter

Display

LCD, max. 4199 dgt., Display refresh rate: 400 ms

Environmental protection

IP40 dustproof and waterproof (while in storage)

Power supply

Coin type lithium battery (CR2032) ×1, Continuous use 120 hours

Core jaw dia.

φ 33 mm (1.30 in)

Dimensions and mass

57 mm (2.24 in) W × 175 mm (6.89 in) H × 16 mm (0.63 in) D, 100 g (3.5 oz)

Included accessories

CARRYING CASE 9398 ×1, TEST LEAD L9208 ×1, Coin type lithium battery (CR2032) ×1, Instruction manual ×1

Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha