Hioki CM4373-93 AC/DC CLAMP METER SOLAR SET (includes DC High Voltage Probe P2010 and Wireless Adapter Z3210)

True RMS 2000 A AC/DC Clamp Meter for the Toughest Situations
With DMM Functions that Deliver Top Safety

Key Features and Functions 

  • CAT IV 600 V, CAT III 1000 V
  • When using P2010: CAT III 2000 V, CAT IV 1000 V
  • Measure DC voltages of up to 2000 V (*1) for open voltage inspections of solar panels
  • Simultaneously measure inrush current in RMS and crest values
  • Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file (*2)
  • Harmonic analysis from 1st to 30th order with GENNECT Cross (*2)
  • Automatic AC/DC function helps boost work efficiency

*1:When using the optional DC High Voltage Probe P2010. The clamp meter itself is capable of measuring up to 1000 V DC.

*2:Wireless Adapter Z3210 is necessary.

Documents and Software:

Price
 
kr 7.851*
* excluding VAT plus shipping

Product Number:

Hioki-CM4373-93

Manufacturer:

Hioki

Quantity:

Total
Unit price
Base Product
Availability:
Call or email for delivery time

Hioki clamp meters are best-in-class measuring devices incorporating Hioki’s expertise in current sensing technology. The CM4373-50 is a 2000 A True RMS clamp meter that features stronger jaws, IP54 dustproof and waterproof enclosure to enable professionals to work quickly in tough situations including the development, repair, and maintenance of equipment and devices such as electric vehicles. Additionally, the high-voltage DC measurement capability of up to 2000 V (*1) is ideal for inspection of solar PV system.

Basic specifications

Accuracy guaranteed: 1 year
 

DC Current range

600.0 A/2000 A, Basic accuracy: ±1.3% rdg. ±0.3 A (600 A range)

AC Current range

600.0 A/2000 A (10 Hz to 1 kHz, True RMS), Basic accuracy 45 - 66 Hz: ±1.3% rdg. ±0.3 A (at 600 A)

Crest factor

600.0 A range: 3 or less
2000 A range: 2.84 or less

DC+AC Current range

600.0 A/2000 A (10 Hz to 1 kHz, True RMS), Basic accuracy DC, 45-66 Hz: ±1.3% rdg. ±1.3 A (at 600 A)

DC Voltage range

600.0 ?V to 1000 V (When using P2010: 600.0 V to 2000 V)

AC Voltage range

6.000 V to 1000 V, 4 ranges (15 Hz to 1 kHz, True RMS), Basic accuracy 45 - 66 Hz: ±0.9% rdg. ±0.003 V (at 6 V)

DC+AC Voltage range

6.000 V to 1000 V, 4 ranges, Basic accuracy DC, 45 - 66 Hz: ±1.0% rdg. ±0.013 V (at 6 V)

Resistance range

600.0 Ω to 6.000 MΩ, 5 ranges, Basic accuracy: ±0.7% rdg. ±0.5 Ω (at 600 Ω)

Capacitance range

1.000 μF to 1000 μF, 4 ranges, Basic accuracy: ±1.9% rdg. ±0.005 μF (at 1 μF)

Frequency range

9.999 Hz to 999.9 Hz, 3 ranges, Basic accuracy: ±0.1% rdg. ±0.003 Hz (at 9.999 Hz)

Temperature (K)

-40.0 to 400.0 ?C, add temperature probe accuracy to basic accuracy of ±0.5% rdg. ±3.0 ?C

Voltage detection

Hi: 40 V to 600 V AC, Lo: 80 V to 600 V AC, 50/60 Hz

Harmonic levels

[With Z3210 installed] Voltage/Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio
*Harmonics can be displayed with our free app GENNECT Cross.

Other functions

DC power, Continuity check, Diode check, Automatic AC/DC detection, Pass/fail judgement function of DC A and DC V, Max/Min/Average/PEAK MAX/ PEAK MIN value display, Low-pass filter function, Display value hold, Auto hold, Back light, Auto-power save, Buzzer sounds, Zero-adjustment, etc.

Dustproof, waterproof

IP20 (Voltage measurement in a completely dry condition. When jaw closes)
IP54 (While in storage)

Power supply

LR03 Alkaline battery ×2
Continuous use: 40 hr (without Z3210 installed), 24 hr. (with Z3210 installed and using wireless communications)
Other conditions: 100 A AC measurement, backlight off, 23°C reference value

Core jaw diameter

φ55 mm (2.17 in), Jaw dimension: 92 mm (3.62 in) W×18 mm (0.71 in) D

Dimensions and mass

65 mm (2.56 in) W×250 mm (9.84 in) H×35 mm (1.38 in) D mm, 530 g (18.7 oz)

Included accessories

Test Lead L9300, Carrying Case C0203, LR03 Alkaline battery ×2, Instruction Manual×2, Operating Precautions ×1

Description
Additional Informations
Reviews
Query on the Item
Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha
Description
Reviews
Query on the Item

Hioki clamp meters are best-in-class measuring devices incorporating Hioki’s expertise in current sensing technology. The CM4373-50 is a 2000 A True RMS clamp meter that features stronger jaws, IP54 dustproof and waterproof enclosure to enable professionals to work quickly in tough situations including the development, repair, and maintenance of equipment and devices such as electric vehicles. Additionally, the high-voltage DC measurement capability of up to 2000 V (*1) is ideal for inspection of solar PV system.

Basic specifications

Accuracy guaranteed: 1 year
 

DC Current range

600.0 A/2000 A, Basic accuracy: ±1.3% rdg. ±0.3 A (600 A range)

AC Current range

600.0 A/2000 A (10 Hz to 1 kHz, True RMS), Basic accuracy 45 - 66 Hz: ±1.3% rdg. ±0.3 A (at 600 A)

Crest factor

600.0 A range: 3 or less
2000 A range: 2.84 or less

DC+AC Current range

600.0 A/2000 A (10 Hz to 1 kHz, True RMS), Basic accuracy DC, 45-66 Hz: ±1.3% rdg. ±1.3 A (at 600 A)

DC Voltage range

600.0 ?V to 1000 V (When using P2010: 600.0 V to 2000 V)

AC Voltage range

6.000 V to 1000 V, 4 ranges (15 Hz to 1 kHz, True RMS), Basic accuracy 45 - 66 Hz: ±0.9% rdg. ±0.003 V (at 6 V)

DC+AC Voltage range

6.000 V to 1000 V, 4 ranges, Basic accuracy DC, 45 - 66 Hz: ±1.0% rdg. ±0.013 V (at 6 V)

Resistance range

600.0 Ω to 6.000 MΩ, 5 ranges, Basic accuracy: ±0.7% rdg. ±0.5 Ω (at 600 Ω)

Capacitance range

1.000 μF to 1000 μF, 4 ranges, Basic accuracy: ±1.9% rdg. ±0.005 μF (at 1 μF)

Frequency range

9.999 Hz to 999.9 Hz, 3 ranges, Basic accuracy: ±0.1% rdg. ±0.003 Hz (at 9.999 Hz)

Temperature (K)

-40.0 to 400.0 ?C, add temperature probe accuracy to basic accuracy of ±0.5% rdg. ±3.0 ?C

Voltage detection

Hi: 40 V to 600 V AC, Lo: 80 V to 600 V AC, 50/60 Hz

Harmonic levels

[With Z3210 installed] Voltage/Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio
*Harmonics can be displayed with our free app GENNECT Cross.

Other functions

DC power, Continuity check, Diode check, Automatic AC/DC detection, Pass/fail judgement function of DC A and DC V, Max/Min/Average/PEAK MAX/ PEAK MIN value display, Low-pass filter function, Display value hold, Auto hold, Back light, Auto-power save, Buzzer sounds, Zero-adjustment, etc.

Dustproof, waterproof

IP20 (Voltage measurement in a completely dry condition. When jaw closes)
IP54 (While in storage)

Power supply

LR03 Alkaline battery ×2
Continuous use: 40 hr (without Z3210 installed), 24 hr. (with Z3210 installed and using wireless communications)
Other conditions: 100 A AC measurement, backlight off, 23°C reference value

Core jaw diameter

φ55 mm (2.17 in), Jaw dimension: 92 mm (3.62 in) W×18 mm (0.71 in) D

Dimensions and mass

65 mm (2.56 in) W×250 mm (9.84 in) H×35 mm (1.38 in) D mm, 530 g (18.7 oz)

Included accessories

Test Lead L9300, Carrying Case C0203, LR03 Alkaline battery ×2, Instruction Manual×2, Operating Precautions ×1

Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha