Hioki CM4375-50 AC/DC CLAMP METER

True RMS 1000 A AC/DC Clamp Meter
Easily Get Into Tight Spaces - Innovative Jaw Provides Remarkable Accessibility

Key Features and Functions

  • CAT IV 600 V, CAT III 1000 V
  • When using P2010: CAT III 2000 V, CAT IV 1000 V
  • Easily get into tight spaces between cables thanks to thin sensor structure
  • Measure DC voltages of up to 2000 V (*1) for open voltage inspections of solar panels
  • Automatic AC/DC function helps boost work efficiency, Measure up to 1000 A
  • Simultaneously measure inrush current in RMS and crest values
  • Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file. (*2)
  • Harmonic analysis from 1st to 30th order with GENNECT Cross (*2)

*1:When using the optional DC High Voltage Probe P2010. The clamp meter itself is capable of measuring up to 1000 V DC.

*2:Wireless Adapter Z3210 is necessary.

Documents and Software:

Price
 
kr 6.682*
* excluding VAT plus shipping

Product Number:

Hioki-CM4375-50

Manufacturer:

Hioki

Quantity:

Total
Unit price
Base Product
Availability:
Typically on stock
On Stock. 1-2 weeks delivery

Hioki clamp on meters are best-in-class measuring devices incorporating Hioki’s expertise in current sensing technology. The CM4375-50 is a 1000 A AC/DC True RMS clamp meter that features a uniquely designed slim jaw that lets you easily get into the narrow gaps between cables in crowded electrical distribution boxes without fear of damaging the cables or the clamp meter. The broad IP54 dustproof and waterproof enclosure to enable professionals to work quickly in challenging situations including the development, repair, and maintenance of equipment and devices such as electric vehicles. Additionally, the high-voltage DC measurement capability of up to 2000 V (*1) is ideal for inspection of solar PV system.

Basic specifications

Accuracy guaranteed: 1 year
 

DC Current range

1000 A, (Max. display 999.9 A) , Basic accuracy: ±1.3% rdg. ±0.3 A (at 30.1 A - 999.9 A)

AC Current range

1000 A (Max. display 999.9 A, 10 Hz to 1 kHz, True RMS), Basic accuracy 45-66 Hz: ±1.8% rdg. ±0.3 A (at 30.1 A - 900.0 A)

Crest factor

1000 A range: 1.5

DC+AC Current range

1000 A (DC, 10 Hz to 1 kHz, True RMS), Basic accuracy DC, 45-66 Hz: ±1.3% rdg. ±1.3 A (at 30.1 A - 900.0 A)

DC Power range

0.000 kVA to 1000 kVA (When using P2010: 0 kVA to 2000 kVA) (Automatically switched based on voltage range), Basic accuracy: ±2.0% rdg. ±20 dgt.

DC Voltage range

600.0 ?V to 1000 V (When using P2010: 600.0 V to 2000 V)

AC Voltage range

6.000 V to 1000 V, 4 ranges (15 Hz to 1 kHz, True RMS), Basic accuracy 45 - 66 Hz: ±0.9% rdg. ±0.003 V (at 6 V)

DC+AC Voltage range

6.000 V to 1000 V, 4 ranges, Basic accuracy DC, 45-66 Hz: ±1.0% rdg. ±0.013 V (at 6 V)

Resistance range

600.0 Ω to 6.000 MΩ, 5 ranges, Basic accuracy: ±0.7% rdg. ±0.5 Ω (at 600 Ω)

Electrostatic capacity range

1.000 μF to 1000 μF, 4 ranges, Basic accuracy: ±1.9% rdg. ±0.005 μF (at 1 μF)

Frequency range

9.999 Hz to 999.9 Hz, 3 ranges, Basic accuracy: ±0.1% rdg. ±0.003 Hz (at 9.999 Hz)

Temperature (K)

-40.0°C to 400.0°C, add temperature probe accuracy to basic accuracy of ±0.5% rdg. ±3.0°C

Harmonic levels

[With Z3210 installed] Voltage/Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio
*Harmonics can be displayed with our free app GENNECT Cross.

Other functions

Continuity check, Diode check, Automatic AC/ DC detection, DC current and DC voltage polarity detection function, MAX/MIN/AVG/ PEAK MAX/PEAK MIN value display, Low-pass filter function, Display value hold, Auto hold, Backlight, Auto power save, Buzzer sound, Zero-adjustment

Dustproof, waterproof

IP20 (Voltage measurement in a completely dry condition. When jaw closes)
IP54 (While in storage)

Power supply

LR03 Alkaline battery ×2
Continuous use: approx. 40 hr (without Z3210 installed), approx. 20 hr. (with Z3210 installed and using wireless communications)
Other conditions: 100 A AC measurement, backlight off, 23°C reference value

Core jaw diameter

φ34 mm (1.34 in)

Smallest dimension of jaw cross-section

9.5 mm (0.37 in) (Range value of 44 mm (1.73 in) from the tip of the jaw)

Dimensions and mass

65 mm (2.56 in) W × 242 mm (9.53 in) H × 35 mm (1.38 in) D mm, 350 g (12.3 oz)

Included accessories

Test Lead L9300, Carrying Case C0203, LR03 Alkaline battery ×2, Instruction Manual ×2, Operating Precautions ×1

Description
Additional Informations
Reviews
Query on the Item
Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha
Description
Reviews
Query on the Item

Hioki clamp on meters are best-in-class measuring devices incorporating Hioki’s expertise in current sensing technology. The CM4375-50 is a 1000 A AC/DC True RMS clamp meter that features a uniquely designed slim jaw that lets you easily get into the narrow gaps between cables in crowded electrical distribution boxes without fear of damaging the cables or the clamp meter. The broad IP54 dustproof and waterproof enclosure to enable professionals to work quickly in challenging situations including the development, repair, and maintenance of equipment and devices such as electric vehicles. Additionally, the high-voltage DC measurement capability of up to 2000 V (*1) is ideal for inspection of solar PV system.

Basic specifications

Accuracy guaranteed: 1 year
 

DC Current range

1000 A, (Max. display 999.9 A) , Basic accuracy: ±1.3% rdg. ±0.3 A (at 30.1 A - 999.9 A)

AC Current range

1000 A (Max. display 999.9 A, 10 Hz to 1 kHz, True RMS), Basic accuracy 45-66 Hz: ±1.8% rdg. ±0.3 A (at 30.1 A - 900.0 A)

Crest factor

1000 A range: 1.5

DC+AC Current range

1000 A (DC, 10 Hz to 1 kHz, True RMS), Basic accuracy DC, 45-66 Hz: ±1.3% rdg. ±1.3 A (at 30.1 A - 900.0 A)

DC Power range

0.000 kVA to 1000 kVA (When using P2010: 0 kVA to 2000 kVA) (Automatically switched based on voltage range), Basic accuracy: ±2.0% rdg. ±20 dgt.

DC Voltage range

600.0 ?V to 1000 V (When using P2010: 600.0 V to 2000 V)

AC Voltage range

6.000 V to 1000 V, 4 ranges (15 Hz to 1 kHz, True RMS), Basic accuracy 45 - 66 Hz: ±0.9% rdg. ±0.003 V (at 6 V)

DC+AC Voltage range

6.000 V to 1000 V, 4 ranges, Basic accuracy DC, 45-66 Hz: ±1.0% rdg. ±0.013 V (at 6 V)

Resistance range

600.0 Ω to 6.000 MΩ, 5 ranges, Basic accuracy: ±0.7% rdg. ±0.5 Ω (at 600 Ω)

Electrostatic capacity range

1.000 μF to 1000 μF, 4 ranges, Basic accuracy: ±1.9% rdg. ±0.005 μF (at 1 μF)

Frequency range

9.999 Hz to 999.9 Hz, 3 ranges, Basic accuracy: ±0.1% rdg. ±0.003 Hz (at 9.999 Hz)

Temperature (K)

-40.0°C to 400.0°C, add temperature probe accuracy to basic accuracy of ±0.5% rdg. ±3.0°C

Harmonic levels

[With Z3210 installed] Voltage/Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio
*Harmonics can be displayed with our free app GENNECT Cross.

Other functions

Continuity check, Diode check, Automatic AC/ DC detection, DC current and DC voltage polarity detection function, MAX/MIN/AVG/ PEAK MAX/PEAK MIN value display, Low-pass filter function, Display value hold, Auto hold, Backlight, Auto power save, Buzzer sound, Zero-adjustment

Dustproof, waterproof

IP20 (Voltage measurement in a completely dry condition. When jaw closes)
IP54 (While in storage)

Power supply

LR03 Alkaline battery ×2
Continuous use: approx. 40 hr (without Z3210 installed), approx. 20 hr. (with Z3210 installed and using wireless communications)
Other conditions: 100 A AC measurement, backlight off, 23°C reference value

Core jaw diameter

φ34 mm (1.34 in)

Smallest dimension of jaw cross-section

9.5 mm (0.37 in) (Range value of 44 mm (1.73 in) from the tip of the jaw)

Dimensions and mass

65 mm (2.56 in) W × 242 mm (9.53 in) H × 35 mm (1.38 in) D mm, 350 g (12.3 oz)

Included accessories

Test Lead L9300, Carrying Case C0203, LR03 Alkaline battery ×2, Instruction Manual ×2, Operating Precautions ×1