Hioki U8552 VOLTAGE/TEMP UNIT

30-channels voltage, temperature, and humidity measurement

  • 30-channels, voltage, temperature (thermocouples), and humidity measurement
  • Sampling rate of up to 20 ms with 30 channels (10 ms sampling is possible when the number of channels used is 15 or less)
  • For DC voltage measurement and temperature measurement using thermocouples

Documents and Software:

Price
 
kr 11.983*
* excluding VAT plus shipping

Product Number:

Hioki-U8552

Manufacturer:

Hioki

Quantity:

Total
Unit price
Base Product
Availability:
Typically on stock
On Stock. 1-2 weeks delivery

Basic specifications

Accuracy guaranteed: 1 year

Connectable instruments

Memory HiLogger LR8450 (Designed for use with plug-in units only)
Memory HiLogger LR8450-01 (Wireless LAN model)

Operating temperature
and humidity

-10°C to 50°C, 80% RH or less (no condensation)

Storage temperature
and humidity

-20°C to 60°C, 80% RH or less (no condensation)

Vibration resistance

JIS D 1601:1995 5.3(1), Class 1A (passenger vehicle) equivalent

Included accessories

Instruction manual × 1, mounting screw × 2

Number of input
channels

30 ch (Able to set voltage, temperature using the thermocouple, and humidity for each channel)

Input terminals

Push-button type terminal block (2 terminals per channel)

Measurement
target

Voltage, temperature using the thermocouple, and humidity

Input type

Scanning by semiconductor relays
All channels isolated (Not isolated when measuring with RTD, resistance, and humidity)

Voltage measurement (resolution)

10 ?V f.s. (500 nV), 20 mV f.s. (1μV), 100 mV f.s. (5μV), 200 mV f.s. (10μV), 1 V f.s. (50μV), 2 V f.s. (100μV), 10 V f.s. (500μV), 20 V f.s. (1 mV), 100 V f.s. (5 mV), 1-5 V f.s. (500μV)

Temperature measurement (thermocouple)

K: -100.00? to 1350.0?
J: -100.00? to 1200.0?
E: -100.00? to 1000.0?
T: -100.00? to 400.0?
N: -100.00? to 1300.0?
R: 0.00? to 1700.0?
S: 0.00? to 1700.0?
B: 400.0? to 1800.0?
C: 0.00? to 2000.0?

Description
Additional Informations
Reviews
Query on the Item
Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha
Description
Reviews
Query on the Item

Basic specifications

Accuracy guaranteed: 1 year

Connectable instruments

Memory HiLogger LR8450 (Designed for use with plug-in units only)
Memory HiLogger LR8450-01 (Wireless LAN model)

Operating temperature
and humidity

-10°C to 50°C, 80% RH or less (no condensation)

Storage temperature
and humidity

-20°C to 60°C, 80% RH or less (no condensation)

Vibration resistance

JIS D 1601:1995 5.3(1), Class 1A (passenger vehicle) equivalent

Included accessories

Instruction manual × 1, mounting screw × 2

Number of input
channels

30 ch (Able to set voltage, temperature using the thermocouple, and humidity for each channel)

Input terminals

Push-button type terminal block (2 terminals per channel)

Measurement
target

Voltage, temperature using the thermocouple, and humidity

Input type

Scanning by semiconductor relays
All channels isolated (Not isolated when measuring with RTD, resistance, and humidity)

Voltage measurement (resolution)

10 ?V f.s. (500 nV), 20 mV f.s. (1μV), 100 mV f.s. (5μV), 200 mV f.s. (10μV), 1 V f.s. (50μV), 2 V f.s. (100μV), 10 V f.s. (500μV), 20 V f.s. (1 mV), 100 V f.s. (5 mV), 1-5 V f.s. (500μV)

Temperature measurement (thermocouple)

K: -100.00? to 1350.0?
J: -100.00? to 1200.0?
E: -100.00? to 1000.0?
T: -100.00? to 400.0?
N: -100.00? to 1300.0?
R: 0.00? to 1700.0?
S: 0.00? to 1700.0?
B: 400.0? to 1800.0?
C: 0.00? to 2000.0?

Do you have any questions on this item?