We use cookies in order to guarantee the best possible service. If you continue browsing the site you consent to our cookie use.

Hioki-BT3562A BATTERY HiTESTER, 100 V DC maximum

Fully Automated Production Line Testing of Large Cells for xEVs or Mid-sized Packs of up to 100 V

  • Measure the voltage of battery packs up to 100 V
  • Production line testing of high-voltage battery packs and battery modules
  • Large (low-resistance) cell testing
  • LAN interface is standard

Documents and Software:

Product Number:

Hioki-BT3562A

Manufacturer:

Hioki

Quantity:

Total
Unit price
base price
Stock
Call or email for delivery time

Hioki benchtop battery testers support simultaneous high-speed measurement of internal resistance and battery voltage for the ever-expanding production lines of increasingly larger lithium-ion low resistance batteries, and other battery packs for high voltage applications. The BT3562A can measure the voltage and resistance of coin-size to large-cell batteries up to 60V almost simultaneously due to their quick response time.

Key Specifications:

  • Resistance measurement ranges:
    • 3 mΩ Max. display: 3.1000 mΩ, resolution: 0.1 μΩ, measurement current: 100 mA
    • 30 mΩ Max. display: 31.000 mΩ, resolution: 1 μΩ, measurement current: 100 mA
    • 300 mΩ Max. display: 310.00 mΩ, resolution: 10 μΩ, measurement current: 10 mA
    • 3 Ω Max. display: 3.1000 Ω, resolution: 100 μΩ, measurement current: 1 mA
    • 30 Ω Max. display: 31.000 Ω, resolution: 1 mΩ, measurement current: 100 μA
    • 300 Ω Max. display: 310.00 Ω, resolution: 10 mΩ, measurement current: 10 μA
    • 3 kΩ Max. display: 3.1000 kΩ, resolution: 100 mΩ, measurement current: 10 μA
    • Basic accuracy: ±0.5% rdg ±10 dgt 3 mΩ range , ±0.5% rdg ±5 dgt 30 mΩ range or more
    • Measurement frequency: 1 kHz ±0.2 Hz
    • Measurement method: AC four-terminal method
  • Voltage measurement ranges:
    • 6 V Max. display: 6.00000 V, resolution: 10 μV
    • 60 V Max. display: 60.0000 V, resolution: 100 μV
    • 100 V Max. display: 100.000 V, resolution: 1 mV
    • Basic accuracy: ±0.01% rdg. ±3 dgt.
  • Response time: 10 ms
  • Sampling period:
    • Ω or V: 4 ms (EX.FAST), 12 ms (FAST), 35 ms (MEDIUM), 150 ms (SLOW)
    • ΩV: 8 ms (EX.FAST), 24 ms (FAST), 70 ms (MEDIUM), 253 ms (SLOW)
  • Functions:
    • Contact check, Zero adjustment (±1000 counts), Pulse measurement, Comparator (Hi/ IN/ Lo), Statistical calculations (Max. 30,000), Delay, Average, Panel saving/loading, Memory storage, LabVIEW® driver
  • Interfaces:
    • LAN (TCP/IP, 10BASE-T/100BASE-TX)
    • RS-232C (Max. 38.4 kbps, Available as printer I/F)
    • EXT I/O (37-pin Handler interface)
    • Analog output (DC 0 V to 3.1 V)
Description
Additional Informations
Reviews
Query on the Item
Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha
Description
Reviews
Query on the Item

Hioki benchtop battery testers support simultaneous high-speed measurement of internal resistance and battery voltage for the ever-expanding production lines of increasingly larger lithium-ion low resistance batteries, and other battery packs for high voltage applications. The BT3562A can measure the voltage and resistance of coin-size to large-cell batteries up to 60V almost simultaneously due to their quick response time.

Key Specifications:

  • Resistance measurement ranges:
    • 3 mΩ Max. display: 3.1000 mΩ, resolution: 0.1 μΩ, measurement current: 100 mA
    • 30 mΩ Max. display: 31.000 mΩ, resolution: 1 μΩ, measurement current: 100 mA
    • 300 mΩ Max. display: 310.00 mΩ, resolution: 10 μΩ, measurement current: 10 mA
    • 3 Ω Max. display: 3.1000 Ω, resolution: 100 μΩ, measurement current: 1 mA
    • 30 Ω Max. display: 31.000 Ω, resolution: 1 mΩ, measurement current: 100 μA
    • 300 Ω Max. display: 310.00 Ω, resolution: 10 mΩ, measurement current: 10 μA
    • 3 kΩ Max. display: 3.1000 kΩ, resolution: 100 mΩ, measurement current: 10 μA
    • Basic accuracy: ±0.5% rdg ±10 dgt 3 mΩ range , ±0.5% rdg ±5 dgt 30 mΩ range or more
    • Measurement frequency: 1 kHz ±0.2 Hz
    • Measurement method: AC four-terminal method
  • Voltage measurement ranges:
    • 6 V Max. display: 6.00000 V, resolution: 10 μV
    • 60 V Max. display: 60.0000 V, resolution: 100 μV
    • 100 V Max. display: 100.000 V, resolution: 1 mV
    • Basic accuracy: ±0.01% rdg. ±3 dgt.
  • Response time: 10 ms
  • Sampling period:
    • Ω or V: 4 ms (EX.FAST), 12 ms (FAST), 35 ms (MEDIUM), 150 ms (SLOW)
    • ΩV: 8 ms (EX.FAST), 24 ms (FAST), 70 ms (MEDIUM), 253 ms (SLOW)
  • Functions:
    • Contact check, Zero adjustment (±1000 counts), Pulse measurement, Comparator (Hi/ IN/ Lo), Statistical calculations (Max. 30,000), Delay, Average, Panel saving/loading, Memory storage, LabVIEW® driver
  • Interfaces:
    • LAN (TCP/IP, 10BASE-T/100BASE-TX)
    • RS-232C (Max. 38.4 kbps, Available as printer I/F)
    • EXT I/O (37-pin Handler interface)
    • Analog output (DC 0 V to 3.1 V)
Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha