We use cookies in order to guarantee the best possible service. If you continue browsing the site you consent to our cookie use.

Hioki-SM7120 SUPER MEGOHM METER, 1ch, max. 2000 V

Rapid 6.4ms Super Megohm and Low Current Testing

Key Features and Functions

  • 300 times better noise resistance
  • Max. 2000 V output : SM7110
  • Max. 2 × 10^19 Ω display
  • Min. 0.1 fA resolution
  • Built-in EXT I/O, RS-232C, GP-IB and USB
  • Flexible, Multipurpose Design, High Resistance Meter/Electrometer/Picoammeter/IR Meter
  • Measure resistance of materials by combining with optional electrode

Documents and Software:

Product Number:

Hioki-SM7120

Manufacturer:

Hioki

Quantity:

Total
Unit price
base price
Stock
Call or email for delivery time

The Hioki SM Series Super Megohm Meters are high resistance and ultra low current inspection devices with a 0.1 fA resolution to offer precise testing on production lines.  To accommodate vehicle components with increasingly high breakdown voltages, the SM7120 is the first insulation tester in the world to be able to output a measurement voltage of 2000 V.

Basic specifications

  • Number of channels: 1 ch
  • DC current measurement:
    • 20 pA range (0.1 fA resolution), Accuracy: ±(2.0 % of rdg. +30 dgt.)
    • 200 pA range (1.0 fA resolution), Accuracy: ±(1.0 % of rdg. +30 dgt.)
    • 2 nA range (10 fA resolution), Accuracy: ±(0.5 % of rdg. +20 dgt.)
    • 20 nA range (100 fA resolution), Accuracy: ±(0.5 % of rdg. +10 dgt.)
    • 200 nA range (1 pA resolution), Accuracy: ±(0.5 % of rdg. +10 dgt.)
    • 2 μA range (10 pA resolution), Accuracy: ±(0.5 % of rdg. +10 dgt.)
    • 20 μA range (100 pA resolution), Accuracy: ±(0.5 % of rdg. +10 dgt.)
    • 200 μA range (1 nA resolution), Accuracy: ±(0.5 % of rdg. +10 dgt.)
    • *2 mA range (1 nA resolution), Accuracy: ±(0.5 % of rdg. +30 dgt.)
      (1) Measurement speed SLOW2 (internal integration time 13PLC)
      (2) At a temperature of 23 °C ±5 °C with humidity of 85% rh
      (3) 2 mA range (Measurement speed FAST only)
  • Resistance measurement capabilities:
    • 50 Ω to 2 × 10 ^19 Ω
      Note: Resistance measurement accuracy is defined by the current range accuracy and voltage setting accuracy.
  • Setting voltage range (Accuracy): 0.1 to 100.0 V, 100 mV resolution, Accuracy: ±0.1 % of setting ±0.05% f.s.
  • 100.1 to 1000 V, 1 V resolution, Accuracy: ±0.1 % of setting ±0.05% f.s.
  • [SM7120 only]
  • 1000 to 2000 V,1 V resolution, Accuracy: ±0.2 % of setting ±0.10% f.s.
  • Current Limiter: 0.1 to 250.0 V: 5/ 10/ 50 mA, 251 to 1000 V: 5/ 10 mA, to 2000 V:1.8 mA
  • Measurement time setting: Delay: 0 to 9,999 ms
  • Functions: Comparator, averaging, self-calibration, jig Capacity open correction, cable length correction, surface resistivity, volume resistivity, voltage monitor, contact check
  • Program function: 10 types of discharge, charge, measure and measurement sequence discharge patterns can be programmed.
  • Display: LCD (8 lines of 30 characters), with backlight, High voltage warning indicator
  • Interfaces: USB, RS-232C, GP-IB, EXT I/O (NPN/PNP can be switched)
Description
Additional Informations
Reviews
Query on the Item
Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha
Description
Reviews
Query on the Item

The Hioki SM Series Super Megohm Meters are high resistance and ultra low current inspection devices with a 0.1 fA resolution to offer precise testing on production lines.  To accommodate vehicle components with increasingly high breakdown voltages, the SM7120 is the first insulation tester in the world to be able to output a measurement voltage of 2000 V.

Basic specifications

  • Number of channels: 1 ch
  • DC current measurement:
    • 20 pA range (0.1 fA resolution), Accuracy: ±(2.0 % of rdg. +30 dgt.)
    • 200 pA range (1.0 fA resolution), Accuracy: ±(1.0 % of rdg. +30 dgt.)
    • 2 nA range (10 fA resolution), Accuracy: ±(0.5 % of rdg. +20 dgt.)
    • 20 nA range (100 fA resolution), Accuracy: ±(0.5 % of rdg. +10 dgt.)
    • 200 nA range (1 pA resolution), Accuracy: ±(0.5 % of rdg. +10 dgt.)
    • 2 μA range (10 pA resolution), Accuracy: ±(0.5 % of rdg. +10 dgt.)
    • 20 μA range (100 pA resolution), Accuracy: ±(0.5 % of rdg. +10 dgt.)
    • 200 μA range (1 nA resolution), Accuracy: ±(0.5 % of rdg. +10 dgt.)
    • *2 mA range (1 nA resolution), Accuracy: ±(0.5 % of rdg. +30 dgt.)
      (1) Measurement speed SLOW2 (internal integration time 13PLC)
      (2) At a temperature of 23 °C ±5 °C with humidity of 85% rh
      (3) 2 mA range (Measurement speed FAST only)
  • Resistance measurement capabilities:
    • 50 Ω to 2 × 10 ^19 Ω
      Note: Resistance measurement accuracy is defined by the current range accuracy and voltage setting accuracy.
  • Setting voltage range (Accuracy): 0.1 to 100.0 V, 100 mV resolution, Accuracy: ±0.1 % of setting ±0.05% f.s.
  • 100.1 to 1000 V, 1 V resolution, Accuracy: ±0.1 % of setting ±0.05% f.s.
  • [SM7120 only]
  • 1000 to 2000 V,1 V resolution, Accuracy: ±0.2 % of setting ±0.10% f.s.
  • Current Limiter: 0.1 to 250.0 V: 5/ 10/ 50 mA, 251 to 1000 V: 5/ 10 mA, to 2000 V:1.8 mA
  • Measurement time setting: Delay: 0 to 9,999 ms
  • Functions: Comparator, averaging, self-calibration, jig Capacity open correction, cable length correction, surface resistivity, volume resistivity, voltage monitor, contact check
  • Program function: 10 types of discharge, charge, measure and measurement sequence discharge patterns can be programmed.
  • Display: LCD (8 lines of 30 characters), with backlight, High voltage warning indicator
  • Interfaces: USB, RS-232C, GP-IB, EXT I/O (NPN/PNP can be switched)
Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha