Hioki-SS7081-50 BATTERY CELL VOLTAGE GENERATOR, 12 channel unit
Efficiently and Safely Validate Battery Management Systems
Key Features and Functions
- Build a highly accurate BMS* validation environment easily and safely (*BMS : Battery Management System)
- Use as voltage generator or simulated battery in place of actual batteries and power supplies to establish an efficient testing environment
Documents and Software:
Stock
Call or email for delivery time
The SS7081-50 a 12-channel battery cell voltage generator that delivers power supply, electronic load, and DMM functionality in a single package. The system's simple architecture makes building an environment for validating BMS functionality safer, more affordable and more productive than ever before.
Basic specifications
- Number of channels: 12
- Maximum in-series connections:
- In-series connections of instrument up to and including a
- maximum in-series output voltage of 1000 V
- Output range:
- DC voltage: 0.0000 V to 5.0250 V (set independently for all channels)
- Maximum output current: ±1.00000 A (set independently for all channels)
- Measurement range:
- DC voltage: -0.00100 V to 5.10000 V
- DC current (2-range architecture): ±1.20000 A (1 A range)
- ±120.0000 μA (100 μA range)
- Integration time:
- 1 PLC (50 Hz: 20 ms; 60 Hz: 16.7 ms) × number of smoothing
- iterations (user-configured)
- Voltage output accuracy: ±0.0150% of setting ±500 μV
- Voltage measurement accuracy: ±0.0100% of reading ±100 μV
- Current measurement accuracy:
- 1 A range: ±0.0700% of reading ±100 μA
- 100 μA range: ±0.0350% of reading ±10 nA
- Interfaces: LAN
Description
Additional Informations
Reviews
Query on the Item
Do you have any questions on this item?
Description
Reviews
Query on the Item
The SS7081-50 a 12-channel battery cell voltage generator that delivers power supply, electronic load, and DMM functionality in a single package. The system's simple architecture makes building an environment for validating BMS functionality safer, more affordable and more productive than ever before.
Basic specifications
- Number of channels: 12
- Maximum in-series connections:
- In-series connections of instrument up to and including a
- maximum in-series output voltage of 1000 V
- Output range:
- DC voltage: 0.0000 V to 5.0250 V (set independently for all channels)
- Maximum output current: ±1.00000 A (set independently for all channels)
- Measurement range:
- DC voltage: -0.00100 V to 5.10000 V
- DC current (2-range architecture): ±1.20000 A (1 A range)
- ±120.0000 μA (100 μA range)
- Integration time:
- 1 PLC (50 Hz: 20 ms; 60 Hz: 16.7 ms) × number of smoothing
- iterations (user-configured)
- Voltage output accuracy: ±0.0150% of setting ±500 μV
- Voltage measurement accuracy: ±0.0100% of reading ±100 μV
- Current measurement accuracy:
- 1 A range: ±0.0700% of reading ±100 μA
- 100 μA range: ±0.0350% of reading ±10 nA
- Interfaces: LAN
Do you have any questions on this item?