ITECH IT8436-600-750 High performance DC electronic load (600 V, 750 A, 30 kW)

DC Modes:

  • Support 8 working modes: CC, CV, CR, CP, CC+CV, CV+CR,CR+CC, CP+CC

Feature set:

  • Max.Voltage : 1200V
  • Current range: 1.5A - 15,000 A
  • Power extended to 600 kW through master-slave connection in parallel
  • High-precision three current measurement ranges with resolution up to 40uA
  • Fast double power loading capability (<3 s)
  • 25kHz fast dynamic mode, current rising and falling time is adjustable
  • 1 kHz continuous sampling rate
  • List programming
  • The battery discharge function is used to test energy storage devices such as batteries and super capacitors
  • CV loop speed is adjustable to match different power supplies 500 kHz voltage and current sampling rate
  • Time measurement, OCP/OPP test short circuit simulation, automatic test
  • Soft start and soft shutdown to prevent voltage fluctuations during on/off
  • I-monitor function
  • Full protection: OVP, UVP, OCP, OPP, OTP, current oscillation protection, current limit, power limit, reverse alarm, etc.
  • Power-off retention memory function, recording up to 100 groups data
  • Independent control, easy to maintain and install.

Connectivity:

  • Built-in standard LAN, USB, RS232, GPIB, CAN and analog, IO interface
  • LabVIEW driver and SCPI protocol

Documents and Software Solutions:

Product Number:

IT8430-600-750

Manufacturer:

ITECH

Quantity:

Total
Unit price
base price
Stock
Call or email for delivery time

Key characteristics

IT8400 high-performance DC electronic load has two voltage levels, 600 V and 1200 V. It supports master-slave connection in parallel with power from 6 kW to 600 kW, and is capable of fast double power loading.

It has three current readback ranges with a resolution of up to 40uA.

IT8400 has faster loop response and current rising and falling speed. It supports up to 8 working modes. It also has dynamic mode, List, OCP, OPP test, automatic test and battery test functions.

IT8400 has built-in CAN, LAN, GPIB, USB, RS232 and analog interfaces, suitable for remote control and system building. In addition, the full protection function makes it well matched with the test of fuel cell, power battery discharge, DC charging pile, BOC, power electronics, solar, automotive high-voltage components, DC-DC, motor and so on.

Fast loading with double power

The input voltage of IT8400 DC electronic load can reach 1200 V. It has a fast double power loading capacity and is available for all models from 6kW to 600kW. You do not need to select the model according to the maximum power during the actual test, which can greatly save your costs. The input over power and loading time are relevant with the temperature of the electronic load. For example: below 30?, IT8400 supports double power loading within 3 seconds. This makes it suitable for instantaneous high-power discharge tests of motors and batteries. For example, simulating the starting of a DC motor, simulating the transient overload characteristics of some power supplies, or instantaneously discharging a high-power battery or fuel cell

Description
Additional Informations
Reviews
Query on the Item
Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha
Description
Reviews
Query on the Item

Key characteristics

IT8400 high-performance DC electronic load has two voltage levels, 600 V and 1200 V. It supports master-slave connection in parallel with power from 6 kW to 600 kW, and is capable of fast double power loading.

It has three current readback ranges with a resolution of up to 40uA.

IT8400 has faster loop response and current rising and falling speed. It supports up to 8 working modes. It also has dynamic mode, List, OCP, OPP test, automatic test and battery test functions.

IT8400 has built-in CAN, LAN, GPIB, USB, RS232 and analog interfaces, suitable for remote control and system building. In addition, the full protection function makes it well matched with the test of fuel cell, power battery discharge, DC charging pile, BOC, power electronics, solar, automotive high-voltage components, DC-DC, motor and so on.

Fast loading with double power

The input voltage of IT8400 DC electronic load can reach 1200 V. It has a fast double power loading capacity and is available for all models from 6kW to 600kW. You do not need to select the model according to the maximum power during the actual test, which can greatly save your costs. The input over power and loading time are relevant with the temperature of the electronic load. For example: below 30?, IT8400 supports double power loading within 3 seconds. This makes it suitable for instantaneous high-power discharge tests of motors and batteries. For example, simulating the starting of a DC motor, simulating the transient overload characteristics of some power supplies, or instantaneously discharging a high-power battery or fuel cell

Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha