ETS-EMSENSE-10 Electric Field Probe, laser-powered
Key Features and Functions
- Laser powered for extended testing
- Frequency corrected field values direct from probe
- No need to apply correction factors
- Single probe frequency range - 10 kHz to 10 GHz
- Broad dynamic range - 1 to 750 V/m
- Small physical size
- Six axis spherical design
- A2LA Accredited Calibration
- Suitable for MIL Standard Specs:
- MIL-STD 461F Radiated Susceptibility (RS)
- Suitable for Automotive Specs:
- SAE J1113/27GMW 3091/3097/3103
- GMW 3091/3097/3103
- FORD FMC 1278
- Suitable for Commercial Specs: EN/IEC 61000-4-3 Radiated Immunity
- To be used in place of the HI-6105 and HI-6122.
Documents and Software Solutions:
Summary
ETS-Lindgren's laser-powered EMSense™ 10 Electric Field Probe embodies the latest innovations in isotropic sensor design, low noise and miniaturized electronics. Designed to be single range reading, the EMSense™ 10 can read data continuously over the entire dynamic range. Data values for each axis (X, Y, and Z) can be read individually or summed. Fiber optic signal and power lines link the RF.
Features
The EMSense 10 probe utilizes an updated CPU in the EMCenter to support its improved communication speed. Some EMCenter units carry an older CPU that must be upgraded to support the EMSense 10 probe and plug-in card. To check compatibility, access the '? Info' menu on the EMCenter main screen and check slot 8. The compatible processor is 7000-008. If the EMCenter shows processor 7000-007, a processor upgrade is available through the ETS-Lindgren service center. Alternatively, a stand-alone EMCenter is available for EMSense 10 that appears as an additional EMCenter slot to EMC control software.
Summary
ETS-Lindgren's laser-powered EMSense™ 10 Electric Field Probe embodies the latest innovations in isotropic sensor design, low noise and miniaturized electronics. Designed to be single range reading, the EMSense™ 10 can read data continuously over the entire dynamic range. Data values for each axis (X, Y, and Z) can be read individually or summed. Fiber optic signal and power lines link the RF.
Features
The EMSense 10 probe utilizes an updated CPU in the EMCenter to support its improved communication speed. Some EMCenter units carry an older CPU that must be upgraded to support the EMSense 10 probe and plug-in card. To check compatibility, access the '? Info' menu on the EMCenter main screen and check slot 8. The compatible processor is 7000-008. If the EMCenter shows processor 7000-007, a processor upgrade is available through the ETS-Lindgren service center. Alternatively, a stand-alone EMCenter is available for EMSense 10 that appears as an additional EMCenter slot to EMC control software.