We use cookies in order to guarantee the best possible service. If you continue browsing the site you consent to our cookie use.

Haefely-PCD 126A Surge Combination Wave 1.2/50 µs…8/20 µs Coupling Network for testing asymmetrical data and control lines, max. 4 wires & Ring Wave 100 kHz Coupling Network for testing symmetrical and asymmetrical data and control lines, max. 4 wire

Product Number:

Haefely-PCD126A

Manufacturer:

Haefely

Quantity:

Total
Unit price
base price
Stock
Call or email for delivery time

The PCD 126A is used for surge coupling of 1,2/50us – 8/20us combination wave impulses onto unshielded asymmetrical data and signal lines according IEC/EN standards. It is also used for surge coupling ring wave impulses onto both unshielded asymmetrical and symmetrical data and control lines according to IEC/EN standards. Up to 6.6 kV peak value are possible. Up to 4 wires can be tested simultaneously. To obtain maximum flexibility only coupling elements are included in the PCD 126A. Decoupling circuits, which depends on the EUT to be tested, can be placed separately in the test setup. Manual coupling path switching for common mode (longitudinal, line to earth) and differential mode (transversal, line to line) testing. Default coupling elements are capacitors, breakdown avalanche diodes and gas arrestors. The coupling elements can be selected easily. The direct coupling output allows the customer to use his own coupling elements.

Description
Additional Informations
Reviews
Query on the Item
Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha
Description
Reviews
Query on the Item

The PCD 126A is used for surge coupling of 1,2/50us – 8/20us combination wave impulses onto unshielded asymmetrical data and signal lines according IEC/EN standards. It is also used for surge coupling ring wave impulses onto both unshielded asymmetrical and symmetrical data and control lines according to IEC/EN standards. Up to 6.6 kV peak value are possible. Up to 4 wires can be tested simultaneously. To obtain maximum flexibility only coupling elements are included in the PCD 126A. Decoupling circuits, which depends on the EUT to be tested, can be placed separately in the test setup. Manual coupling path switching for common mode (longitudinal, line to earth) and differential mode (transversal, line to line) testing. Default coupling elements are capacitors, breakdown avalanche diodes and gas arrestors. The coupling elements can be selected easily. The direct coupling output allows the customer to use his own coupling elements.

Do you have any questions on this item?