We use cookies in order to guarantee the best possible service. If you continue browsing the site you consent to our cookie use.

Hioki-IM3570 IMPEDANCE ANALYZER, 4 Hz to 5 MHz

Single Device Solution for High Speed Testing and Frequency Sweeping

Key Features and Functions

  • LCR measurement, DCR measurement, sweep measurement, continuous measurement and high-speed testing achieved with one instrument
  • High-speed testing, achieving maximum speeds of 1.5ms (1 kHz) and 0.5ms (100kHz) in LCR mode
  • High-accuracy measurements, basic accuracy of Z parameter: ± 0.08%
  • Perfect impedance analyzer for testing the resonance characteristics of piezoelectric elements, C-D and low ESR measurement of functional polymer capacitors, DCR and L-Q measurement of inductors (coils and transformers)
  • Perform frequency sweeps, level sweeps, and time interval measurements in analyzer mode

Documents and Software:

Product Number:

Hioki-IM3570

Manufacturer:

Hioki

Quantity:

Total
Unit price
base price
Stock
Call or email for delivery time

Hioki LCR Meters and Impedance Analyzers range from 1mHz to 3GHz devices to suit a wide range of applications in the testing of electronic components. The IM3570 is ideal for use in applications requiring low-ESR measurement on the order of several milliohms, for example testing of functional polymer capacitors, due to its superior low-impedance repeatability.

Key Specifications:

  • Measurement modes: LCR mode, Analyzer mode (Sweeps with measurement frequency and measurement level), Continuous measurement mode
  • Measurement parameters: Z, Y, θ, Rs (ESR), Rp, Rdc (DC resistance), X, G, B, Cs, Cp, Ls, Lp,
  • D (tanδ), Q
  • Measurement range: 100 mΩ to 100 MΩ, 12 ranges (All parameters are determined according to Z)
  • Display range:
    • Z, Y, Rs, Rp, Rdc, X, G, B, Ls, Lp, Cs, Cp :
    • ±(0.000000 [unit] to 9.999999G [unit], Absolute value display for Z and Y only
    • θ : ±(0.000° to 180.000°), D : ±(0.000000 to 9.999999)
    • Q : ±(0.00 to 99999.99), Δ % : ±(0.0000% to 999.9999%)
  • Basic accuracy: Z ±0.08% rdg. θ: ±0.05°
  • Measurement frequency: 4 Hz to 5 MHz (5 digits setting resolution, minimum resolution 10 mHz)
  • Measurement signal level:
    • Normal mode:
    • V mode/CV mode: 5 mV to 5 Vrms (up to 1 MHz)
    • 10 mV to 1 Vrms (1.0001 MHz to 5 MHz), 1 mVrms steps
    • CC mode: 10 μA to 50 mArms (up to 1 MHz)
    • 10 μA to 10 mArms (1.0001 MHz to 5 MHz), 10 μArms steps
    • Low impedance high accuracy mode:
    • V mode/CV mode: 5 mV to 1 Vrms (up to 100 kHz), 1 mVrms steps
    • CC mode:10 μA to 100 mArms (100 mΩ and 1Ω ranges of up to 100 kHz), 10 μArms steps
  • Output impedance: Normal mode: 100 Ω, Low impedance high accuracy mode: 10 Ω
  • Display: 5.7-inch color TFT, display can be set to ON/OFF
  • Measurement time: 0.5 ms (100 kHz, FAST, display OFF, representative value)
  • Functions: DC bias measurement, Comparator, BIN measurement (classification), Panel loading/saving, Memory function
  • Interfaces: EXT I/O (handler), RS-232C, GP-IB, USB communication, USB memory, LAN
Description
Additional Informations
Reviews
Query on the Item
Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha
Description
Reviews
Query on the Item

Hioki LCR Meters and Impedance Analyzers range from 1mHz to 3GHz devices to suit a wide range of applications in the testing of electronic components. The IM3570 is ideal for use in applications requiring low-ESR measurement on the order of several milliohms, for example testing of functional polymer capacitors, due to its superior low-impedance repeatability.

Key Specifications:

  • Measurement modes: LCR mode, Analyzer mode (Sweeps with measurement frequency and measurement level), Continuous measurement mode
  • Measurement parameters: Z, Y, θ, Rs (ESR), Rp, Rdc (DC resistance), X, G, B, Cs, Cp, Ls, Lp,
  • D (tanδ), Q
  • Measurement range: 100 mΩ to 100 MΩ, 12 ranges (All parameters are determined according to Z)
  • Display range:
    • Z, Y, Rs, Rp, Rdc, X, G, B, Ls, Lp, Cs, Cp :
    • ±(0.000000 [unit] to 9.999999G [unit], Absolute value display for Z and Y only
    • θ : ±(0.000° to 180.000°), D : ±(0.000000 to 9.999999)
    • Q : ±(0.00 to 99999.99), Δ % : ±(0.0000% to 999.9999%)
  • Basic accuracy: Z ±0.08% rdg. θ: ±0.05°
  • Measurement frequency: 4 Hz to 5 MHz (5 digits setting resolution, minimum resolution 10 mHz)
  • Measurement signal level:
    • Normal mode:
    • V mode/CV mode: 5 mV to 5 Vrms (up to 1 MHz)
    • 10 mV to 1 Vrms (1.0001 MHz to 5 MHz), 1 mVrms steps
    • CC mode: 10 μA to 50 mArms (up to 1 MHz)
    • 10 μA to 10 mArms (1.0001 MHz to 5 MHz), 10 μArms steps
    • Low impedance high accuracy mode:
    • V mode/CV mode: 5 mV to 1 Vrms (up to 100 kHz), 1 mVrms steps
    • CC mode:10 μA to 100 mArms (100 mΩ and 1Ω ranges of up to 100 kHz), 10 μArms steps
  • Output impedance: Normal mode: 100 Ω, Low impedance high accuracy mode: 10 Ω
  • Display: 5.7-inch color TFT, display can be set to ON/OFF
  • Measurement time: 0.5 ms (100 kHz, FAST, display OFF, representative value)
  • Functions: DC bias measurement, Comparator, BIN measurement (classification), Panel loading/saving, Memory function
  • Interfaces: EXT I/O (handler), RS-232C, GP-IB, USB communication, USB memory, LAN
Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha