Hioki-IM7580A-1 IMPEDANCE ANALYZER, 1 MHz to 300 MHz
1MHz to 300MHz Measurement Frequency Impedance Analyzer with 0.5ms Test Speed and Superior Repeatability
Key Features and Functions
- 1 MHz to 300 MHz testing source frequency
- Fastest test speed of 0.5 msec
- ±0.72% rdg. basic accuracy
- Half-rack size body and palm-sized test head
- Comprehensive contact check (via DCR testing, Hi-Z reject or waveform judgment)
- Make frequency sweeps, level sweeps and time interval measurements in Analyzer Mode
Documents and Software:
Hioki LCR Meters and Impedance Analyzers range from 1mHz to 3GHz devices to suit a wide range of applications in the testing of electronic components. The IM7580A impedance analyzer offers a top measurement time of 0.5ms over a 1MHz to 300MHz frequency, and both LCR and Analyzer Modes to meet applications for both high volume production inspections and research and development.
Key Specifications:
- Measurement modes: LCR mode, Analyzer mode (Sweeps with measurement frequency and measurement level), Continuous measurement mode
- Measurement parameters: Z, Y, θ, Rs (ESR), Rp, X, G, B, Cs, Cp, Ls, Lp, D (tanδ), Q
- Measurable range: 100 mΩ to 5 kΩ
- Display range:
- Z: 0.00 m to 9.99999 GΩ / Rs, Rp, X: ± (0.00 m to 9.99999 GΩ)
- Ls, Lp: ± (0.00000 n to 9.99999 GH) / Q: ± (0.00 to 9999.99)
- θ: ± (0.000° to 180.000°), Cs, Cp: ± (0.00000 p to 9.99999 GF)
- D: ± (0.00000 to 9.99999), Y: (0.000 n to 9.99999 GS)
- G, B: ± (0.000 n to 9.99999 GS), Δ%: ± (0.000 % to 999.999 %)
- Basic accuracy: Z: ±0.72 % rdg. θ: ±0.41°
- Measurement frequency: 1.0000 MHz to 300.00 MHz (5 digits resolution)
- Measurement signal level:
- Power: -40.0 dBm to +7.0 dBm
- Voltage: 4 mV to 1001 mVrms
- Current: 0.09 mA to 20.02 mArms
- Output impedance: 50 Ω
- Display: 8.4-inch color TFT with touch screen
- Measurement speeds *1: FAST: 0.5 ms (Analog measurement time, typical value)
- Functions: Contact check, Comparator, BIN measurement (classification), Panel loading/saving, Memory function, Equivalent circuit analysis, Correlation compensation
- Interfaces: EXT I/O (Handler), USB communication, USB memory, LAN, RS-232C (optional), GP-IB (optional)
Hioki LCR Meters and Impedance Analyzers range from 1mHz to 3GHz devices to suit a wide range of applications in the testing of electronic components. The IM7580A impedance analyzer offers a top measurement time of 0.5ms over a 1MHz to 300MHz frequency, and both LCR and Analyzer Modes to meet applications for both high volume production inspections and research and development.
Key Specifications:
- Measurement modes: LCR mode, Analyzer mode (Sweeps with measurement frequency and measurement level), Continuous measurement mode
- Measurement parameters: Z, Y, θ, Rs (ESR), Rp, X, G, B, Cs, Cp, Ls, Lp, D (tanδ), Q
- Measurable range: 100 mΩ to 5 kΩ
- Display range:
- Z: 0.00 m to 9.99999 GΩ / Rs, Rp, X: ± (0.00 m to 9.99999 GΩ)
- Ls, Lp: ± (0.00000 n to 9.99999 GH) / Q: ± (0.00 to 9999.99)
- θ: ± (0.000° to 180.000°), Cs, Cp: ± (0.00000 p to 9.99999 GF)
- D: ± (0.00000 to 9.99999), Y: (0.000 n to 9.99999 GS)
- G, B: ± (0.000 n to 9.99999 GS), Δ%: ± (0.000 % to 999.999 %)
- Basic accuracy: Z: ±0.72 % rdg. θ: ±0.41°
- Measurement frequency: 1.0000 MHz to 300.00 MHz (5 digits resolution)
- Measurement signal level:
- Power: -40.0 dBm to +7.0 dBm
- Voltage: 4 mV to 1001 mVrms
- Current: 0.09 mA to 20.02 mArms
- Output impedance: 50 Ω
- Display: 8.4-inch color TFT with touch screen
- Measurement speeds *1: FAST: 0.5 ms (Analog measurement time, typical value)
- Functions: Contact check, Comparator, BIN measurement (classification), Panel loading/saving, Memory function, Equivalent circuit analysis, Correlation compensation