We use cookies in order to guarantee the best possible service. If you continue browsing the site you consent to our cookie use.

Keysight N1021B Differential TDR Probe Kit

Key Features

N1021B Differential Time-Domain Reflectometry and Time-Domain Transmission

  • Bandwidth 18 GHz
  • 100 Ohm nominal differential impedance
  • Variable tip spacing: 0.0-2.54mm
  • Spring loaded probe tips with independent Z-axis movement

Addtional documents and Software Solutions:

Product Number:

N1021B

Manufacturer:

Keysight Technologies

Quantity:

Total
Unit price
base price
Stock
Call or email for delivery time

N1021B Differential Time-Domain Reflectometry and Time-Domain Transmission Probe Kit Details

The N1021B is an ergonomically designed handheld probe to interface TDR/TDT modules such as the 54754A to printed circuit boards (PCBs) and components that lack common coaxial high-frequency connectors. The built-in wheel adjusts the pitch between the differential tips to make good contact to pads or access points spaced from closed to typical IC pins (2.54 mm).

Engineers working on high-speed differential electrical channels can analyze where the device under test (DUT) causes reflections that unfavorably affect the signal integrity (SI) of their designs. Manufacturers of printed circuit boards (PCB) can control process consistency from batch to batch, and/or locate the position of shorts, opens or other flaws.

The N1021B probe is used in conjunction with the following: a) the industry-standard 86100C Infiniium DCA-J Wideband Oscilloscope Mainframe, b) the 86100C-202 Enhanced Impedance and S-Parameter Software, and c) the 54754A Differential & Single-ended TDR-TDT Module. The N1021B probe launches small electrical steps in the DUT (device under test) and/or receives the response, which is processed and displayed in the time domain or as S-parameters (SDD11, SDD22, SDD21 or SDD22). Time-domain measurements can display the reflected voltages or obser ved impedances versus time or distance. S-parameter measurements include magnitude, phase and group delay.

The N1021B kit consists of these elements:
Qty.  Description  Replacement1:
1 Differential TDR Probe  -
Pair of matched cables (1 m)  N1021-60003
SMA Short (m)  0960-0055
SMA Load 50 Ohm (m)  1810-0118
2 SMA Adapter (f-f)  1250-1666
  Adapter to positioners (includes two 2.5 mm screws and one Allen wrench) N1021-60008
ESD Wrist strap  9300-1367
ESD Wrist strap ground cord  9300-0980
ESD warning label stickers  -
  User's Guide (either printed or on CD) -
Box with foam insert  -

1 Replacement parts can be bought at Keysight's Test & Measurement Parts Catalog

The Keysight N1021B TDR 18 GHz differential TDR probe kit connects printed circuit boards and other devices without connectors to the 54754A differential TDR/TDT module in the 86100 Infiniium DCA wideband oscilloscope mainframe.

Description
Additional Informations
Reviews
Query on the Item
Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha
Description
Reviews
Query on the Item

N1021B Differential Time-Domain Reflectometry and Time-Domain Transmission Probe Kit Details

The N1021B is an ergonomically designed handheld probe to interface TDR/TDT modules such as the 54754A to printed circuit boards (PCBs) and components that lack common coaxial high-frequency connectors. The built-in wheel adjusts the pitch between the differential tips to make good contact to pads or access points spaced from closed to typical IC pins (2.54 mm).

Engineers working on high-speed differential electrical channels can analyze where the device under test (DUT) causes reflections that unfavorably affect the signal integrity (SI) of their designs. Manufacturers of printed circuit boards (PCB) can control process consistency from batch to batch, and/or locate the position of shorts, opens or other flaws.

The N1021B probe is used in conjunction with the following: a) the industry-standard 86100C Infiniium DCA-J Wideband Oscilloscope Mainframe, b) the 86100C-202 Enhanced Impedance and S-Parameter Software, and c) the 54754A Differential & Single-ended TDR-TDT Module. The N1021B probe launches small electrical steps in the DUT (device under test) and/or receives the response, which is processed and displayed in the time domain or as S-parameters (SDD11, SDD22, SDD21 or SDD22). Time-domain measurements can display the reflected voltages or obser ved impedances versus time or distance. S-parameter measurements include magnitude, phase and group delay.

The N1021B kit consists of these elements:
Qty.  Description  Replacement1:
1 Differential TDR Probe  -
Pair of matched cables (1 m)  N1021-60003
SMA Short (m)  0960-0055
SMA Load 50 Ohm (m)  1810-0118
2 SMA Adapter (f-f)  1250-1666
  Adapter to positioners (includes two 2.5 mm screws and one Allen wrench) N1021-60008
ESD Wrist strap  9300-1367
ESD Wrist strap ground cord  9300-0980
ESD warning label stickers  -
  User's Guide (either printed or on CD) -
Box with foam insert  -

1 Replacement parts can be bought at Keysight's Test & Measurement Parts Catalog

The Keysight N1021B TDR 18 GHz differential TDR probe kit connects printed circuit boards and other devices without connectors to the 54754A differential TDR/TDT module in the 86100 Infiniium DCA wideband oscilloscope mainframe.