Keysight E5052B 10 MHz to 7 GHz Signal Source Analyzer
Frequency range
- RF Input frequency range: 10 MHz to 110 GHz
- Analysis offset frequency range: 1 Hz to 100 MHz
- Phase noise measurement with ultra low noise floor and a cross-correlation method
- Frequency transient capture range: up to 80 MHz in narrow band, up to 4.8 GHz in wide band
Noise measurement functions
- Phase noise with ultra low noise floor and a cross-correlation method
- AM noise measurement and phase noise measurement without changing RF connection
- Baseband noise measurement from 1 Hz to 100 MHz
- Spectrum monitoring up to 15 MHz span in a real-time mode
Analysis capabilities
- Simultaneous transient measurements for frequency, phase and power over time
- Capture of unexpected frequency change with video trigger function
- Complete VCO characterization with outstanding low-noise DC sources(frequency/power/DC-supply-current over Vc and Vs)
- Clock jitter measurement with femto-second resolution
Stock
Call or email for delivery time
Frequency range
- RF Input frequency range: 10 MHz to 110 GHz
- Analysis offset frequency range: 1 Hz to 100 MHz
- Phase noise measurement with ultra low noise floor and a cross-correlation method
- Frequency transient capture range: up to 80 MHz in narrow band, up to 4.8 GHz in wide band
Noise measurement functions
- Phase noise with ultra low noise floor and a cross-correlation method
- AM noise measurement and phase noise measurement without changing RF connection
- Baseband noise measurement from 1 Hz to 100 MHz
- Spectrum monitoring up to 15 MHz span in a real-time mode
Analysis capabilities
- Simultaneous transient measurements for frequency, phase and power over time
- Capture of unexpected frequency change with video trigger function
- Complete VCO characterization with outstanding low-noise DC sources(frequency/power/DC-supply-current over Vc and Vs)
- Clock jitter measurement with femto-second resolution
Addtional document
- Brochure
Description
Additional Informations
Reviews
Query on the Item
Do you have any questions on this item?
Description
Reviews
Query on the Item
Frequency range
- RF Input frequency range: 10 MHz to 110 GHz
- Analysis offset frequency range: 1 Hz to 100 MHz
- Phase noise measurement with ultra low noise floor and a cross-correlation method
- Frequency transient capture range: up to 80 MHz in narrow band, up to 4.8 GHz in wide band
Noise measurement functions
- Phase noise with ultra low noise floor and a cross-correlation method
- AM noise measurement and phase noise measurement without changing RF connection
- Baseband noise measurement from 1 Hz to 100 MHz
- Spectrum monitoring up to 15 MHz span in a real-time mode
Analysis capabilities
- Simultaneous transient measurements for frequency, phase and power over time
- Capture of unexpected frequency change with video trigger function
- Complete VCO characterization with outstanding low-noise DC sources(frequency/power/DC-supply-current over Vc and Vs)
- Clock jitter measurement with femto-second resolution
Addtional document
- Brochure