We use cookies in order to guarantee the best possible service. If you continue browsing the site you consent to our cookie use.

Hioki-IM3590 CHEMICAL IMPEDANCE ANALYZER

For R & D applications of Electrochemical Components and Materials, Batteries, and EDLCs

Key Features and Functions

  • Broad 1 mHz to 200 kHz signal source range supports measurements of ion behavior and solution resistance
  • Continuous measuring and high-speed testing of LCR and sweep measurements with a single instrument
  • Measure internal impedance of batteries with no load
  • Perform high-speed sweep measurements in as little as 2 ms
  • Basic accuracy of ±0.05% is ideal for applications from component testing to R&D
  • Measure LCR impedance for Cole-Cole plots and equivalent-circuit analyses of electro-chemical components and materials

Documents and Software:

Product Number:

Hioki-IM3590

Manufacturer:

Hioki

Quantity:

Total
Unit price
base price
Stock
Call or email for delivery time

Hioki LCR Meters and Impedance Analyzers range from 1mHz to 3GHz devices to suit a wide range of applications in the testing of electronic components.. The IM3590 impedance analyzer is an advanced component tester especially suited to electrochemical impedance measurements and includes a variety of graphing functions that are needed for battery and chemical material testing.

Key Specifications:

  • Measurement modes: LCR mode, Continuous measurement mode (LCR mode / Analyzer mode), Analyzer mode (Sweeps with measurement frequency and measurement level, temperature characteristics, equivalent circuit analysis)
  • Measurement parameters: Z, Y, θ, Rs (ESR), Rp, Rdc (DC resistance), X, G, B, Cs, Cp, Ls, Lp,
  • D (tanδ), Q, T, σ (conductivity), ε (dielectric constant)
  • Measurement range: 100 mΩ to 100 MΩ, 10 ranges (All parameters are determined according to Z)
  • Display range:
    • Z, Y, Rs, Rp, Rdc, X, G, B, Ls, Lp, Cs, Cp, σ, ε :
    • ±(0.00000 [unit] to 9.99999G [unit], Absolute value display for Z and Y only
    • θ : ±(0.000° to 180.000°), D : ±(0.00000 to 9.99999)
    • Q : ±(0.00 to 99999.9), Δ % : ±(0.0000% to 999.999%)
    • T : -10.0°C to 99.9°C
    • σ, ε :±(0.00000f [unit] to 999.999G [unit]
  • Basic accuracy: Z: ±0.05% rdg. θ: ±0.03°
  • Measurement frequency: 1 mHz to 200 kHz (5 digits setting resolution, minimum resolution 1 mHz)
  • Measurement signal level:
    • Normal mode:
    • V mode/CV mode: 5 mV to 5 Vrms, 1 mVrms steps
    • CC mode: 10 μA to 50 mArms, 10 μArms steps
    • Low impedance high accuracy mode:
    • V mode/CV mode: 5 mV to 2.5 Vrms, 1 mVrms steps
    • CC mode:10 μA to 100 mArms, 10 μArms steps
  • Output impedance: Normal mode: 100 Ω, Low impedance high accuracy mode: 25 Ω
  • Display: 5.7-inch color TFT, display can be set to ON/OFF
  • Measurement time: 2 ms (1 kHz, FAST, display OFF, representative value)
  • Functions: DC bias measurement, DC resistance temperature compensation (converted reference temperature is displayed), Temperature measurement, Battery mesurement (Automatic DC biasing system), Comparator, BIN measurement (classification), Panel loading/saving, Memory function
  • Interfaces:
    • EXT I/O (Handler), USB communication (high-speed), USB memory
    • Optional: Choose 1 from RS-232C, GP-IB, or LAN
Description
Additional Informations
Reviews
Query on the Item
Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha
Description
Reviews
Query on the Item

Hioki LCR Meters and Impedance Analyzers range from 1mHz to 3GHz devices to suit a wide range of applications in the testing of electronic components.. The IM3590 impedance analyzer is an advanced component tester especially suited to electrochemical impedance measurements and includes a variety of graphing functions that are needed for battery and chemical material testing.

Key Specifications:

  • Measurement modes: LCR mode, Continuous measurement mode (LCR mode / Analyzer mode), Analyzer mode (Sweeps with measurement frequency and measurement level, temperature characteristics, equivalent circuit analysis)
  • Measurement parameters: Z, Y, θ, Rs (ESR), Rp, Rdc (DC resistance), X, G, B, Cs, Cp, Ls, Lp,
  • D (tanδ), Q, T, σ (conductivity), ε (dielectric constant)
  • Measurement range: 100 mΩ to 100 MΩ, 10 ranges (All parameters are determined according to Z)
  • Display range:
    • Z, Y, Rs, Rp, Rdc, X, G, B, Ls, Lp, Cs, Cp, σ, ε :
    • ±(0.00000 [unit] to 9.99999G [unit], Absolute value display for Z and Y only
    • θ : ±(0.000° to 180.000°), D : ±(0.00000 to 9.99999)
    • Q : ±(0.00 to 99999.9), Δ % : ±(0.0000% to 999.999%)
    • T : -10.0°C to 99.9°C
    • σ, ε :±(0.00000f [unit] to 999.999G [unit]
  • Basic accuracy: Z: ±0.05% rdg. θ: ±0.03°
  • Measurement frequency: 1 mHz to 200 kHz (5 digits setting resolution, minimum resolution 1 mHz)
  • Measurement signal level:
    • Normal mode:
    • V mode/CV mode: 5 mV to 5 Vrms, 1 mVrms steps
    • CC mode: 10 μA to 50 mArms, 10 μArms steps
    • Low impedance high accuracy mode:
    • V mode/CV mode: 5 mV to 2.5 Vrms, 1 mVrms steps
    • CC mode:10 μA to 100 mArms, 10 μArms steps
  • Output impedance: Normal mode: 100 Ω, Low impedance high accuracy mode: 25 Ω
  • Display: 5.7-inch color TFT, display can be set to ON/OFF
  • Measurement time: 2 ms (1 kHz, FAST, display OFF, representative value)
  • Functions: DC bias measurement, DC resistance temperature compensation (converted reference temperature is displayed), Temperature measurement, Battery mesurement (Automatic DC biasing system), Comparator, BIN measurement (classification), Panel loading/saving, Memory function
  • Interfaces:
    • EXT I/O (Handler), USB communication (high-speed), USB memory
    • Optional: Choose 1 from RS-232C, GP-IB, or LAN
Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha