Hioki PW4001-01 4-channel Compact Power Analyzer
Portable 4-channel power analyzer with ±0.04% basic accuracy, DC to 600 kHz frequency bandwidth, CAT II 1500 V DC, 1 ms data update rate, waveform & D/A output, motor analysis, external DC power input
Key Specifications
- 4-channel compact power analyzer featuring:
- DC & 50/60 Hz power accuracy ±0.03% of reading ±0.01% of range
- Wide operating temperature range from -20°C to +50°C
- Lightweight at 4.6 kg
- 600 kHz measurement frequency band
- 2.5 MHz, 16-bit sampling performance
- 15 GB internal memory
- CAN input/output functionality
- AC power supply input from 100 to 240 V
- DC power supply input from 10.8 to 28 V (Option)
Key Features and Functions
- Easy power measurement with clamp current sensors
- 4 voltage channnels and 4 current channels
- Accuracy of DC and 50/60 Hz that meets WLTP and SAE J1634 requirements
- Excellent environmental durability suitable for low-temperature testing of EVs and batteries (e.g., -10°C, -20°C, respectively)
- Weight: 4.6 kg(162.26 oz.), small and light enough to be held with one hand
- 15 GB internal memory for storing setting files, measured data, and screenshots
- Measured data can be converted to CAN format and output, enabling easy data integration with CAN analysis software (CAN output function)
- CAN data and measured data can be saved simultaneously (CAN input function)
- CAN data can be acquired via vehicle diagnostic communication using OBD-II/OBDonUDS (CAN input function)
- Data can be saved at intervals as fast as 1 ms
- Simultaneous parallel calculation of all parameters such as RMS, harmonics, instantaneous waveforms, and efficiency
More Information:
Product Overview
The HIOKI PW4001 is a portable 4-channel power analyzer that combines compact design with laboratory-grade precision. With a basic accuracy of ±0.04% across a frequency range from DC to 600 kHz, and benchmark accuracy of ±0.03% rdg. ±0.01% f.s. at DC and 50/60 Hz, it provides the precision required for applications like WLTP (Worldwide harmonized Light vehicles Test Procedure) testing, DC-DC converter efficiency evaluation, and other demanding measurement tasks in R&D, production, and field environments.
The power analyzer supports direct voltage input up to 1500 V DC (CAT II) and 1000 V DC (CAT III), enabling measurements in high-voltage environments such as photovoltaic inverters and other modern power conversion systems. Furthermore, its CAN input function allows the PW4001 to obtain battery voltage values via CAN communication, so that power can be calculated without direct voltage probing. This is particularly important in environments where safety considerations make direct access to terminals difficult, for example when testing fully assembled electric vehicles.
The combination of a fixed four-channel design, high accuracy, and wide frequency bandwidth makes the PW4001 ideally suited for efficiency testing of single-stage converters. Typical applications include energy storage system (ESS) converters and the inverter stages used in heat pumps, compressor drives, and basic industrial motor drives, where DC input and AC output can be measured simultaneously.
Overview of PW4001 Models
| Model | D/A Output | Motor Analysis | DC power supply |
|---|---|---|---|
| PW4001-01 | No | No | No |
| PW4001-02 | Yes | No | No |
| PW4001-03 | No | Yes | No |
| PW4001-04 | No | No | Yes |
| PW4001-05 | Yes | Yes | Yes |
Product Overview
The HIOKI PW4001 is a portable 4-channel power analyzer that combines compact design with laboratory-grade precision. With a basic accuracy of ±0.04% across a frequency range from DC to 600 kHz, and benchmark accuracy of ±0.03% rdg. ±0.01% f.s. at DC and 50/60 Hz, it provides the precision required for applications like WLTP (Worldwide harmonized Light vehicles Test Procedure) testing, DC-DC converter efficiency evaluation, and other demanding measurement tasks in R&D, production, and field environments.
The power analyzer supports direct voltage input up to 1500 V DC (CAT II) and 1000 V DC (CAT III), enabling measurements in high-voltage environments such as photovoltaic inverters and other modern power conversion systems. Furthermore, its CAN input function allows the PW4001 to obtain battery voltage values via CAN communication, so that power can be calculated without direct voltage probing. This is particularly important in environments where safety considerations make direct access to terminals difficult, for example when testing fully assembled electric vehicles.
The combination of a fixed four-channel design, high accuracy, and wide frequency bandwidth makes the PW4001 ideally suited for efficiency testing of single-stage converters. Typical applications include energy storage system (ESS) converters and the inverter stages used in heat pumps, compressor drives, and basic industrial motor drives, where DC input and AC output can be measured simultaneously.
Overview of PW4001 Models
| Model | D/A Output | Motor Analysis | DC power supply |
|---|---|---|---|
| PW4001-01 | No | No | No |
| PW4001-02 | Yes | No | No |
| PW4001-03 | No | Yes | No |
| PW4001-04 | No | No | Yes |
| PW4001-05 | Yes | Yes | Yes |