ITECH IT7805 High Power AC/DC Power Supply (350 V, 30 A, 5 kVA, 1 phase)

Key Features and Functions

  • 5kVA - 3U high
  • High power density, 3U up to 15kVA
  • Master-slave parallel with current sharing technology, up to 960kVA
  • Voltage up to 350V L-N
  • Output frequency: 16-2400Hz
  • Built-in AC power meter
  • Output modes: AC/DC/AC+DC/DC+AC
  • Interfaces:
    • Standard: USB/CAN/LAN/Digital IO
    • Options: GPIB/Analog/RS232

Documents and Software Solutions:

Product Number:

IT7805-350-30U

Manufacturer:

ITECH

Quantity:

Total
Unit price
base price
Stock
Call or email for delivery time

ITECH IT7800 series of programmable AC/DC power supply, with power up to 15 kVA per 3U hight, voltage ranges up to 350 V L-N and 500 V L-N. Users are able to increase output power up to 960 kVA by configuring master-slave parallel. With intuitive LCD touch panel interface, users can be quickly familiar with the unit operation.

IT7800 series is built-in power meter and arbitrary waveform generator, which is able to simulate harmonics and other arbitrary waveform output. Users can choose single phase, three-phase, phase reversal, and multi-channel totally 4 output modes, with programmable output, and complete measurements, ITECH IT7800 series is designed for new energy, power electronics, research institutes etc.

Additional features:

  • Multi-channel function, single unit can connect/test up to 3 DUTs
  • Choose single phase, three-phase, reverse phase output mode, to simulate 3-phase imbalance, 3-phase harmonics imbalance, split phase test, reverse phase sequence tests etc.
  • Comprehensive harmonics measurement and analysis, up to 50th
  • Intuitive touch screen interface
  • Simulate arbitrary waveform output, support csv. file import
  • Standard waveforms build in
  • List mode simulates the power supply reproduction function to realize the simulation function of
  • instantaneous power interruption
  • Trigger input and output signals. 
  • Output 0-360 ° start/stop phase angle can be set
  • Surge/Sag function
  • Output relay function

Key Specifications (15 kVA model):

  • AC output:
    • Output voltage:
      • Line to Neutral: 350 Volt
      • Line to Line: 606 Volt
    • Output current:
      • RMS: 90 A (1phase) / 30A (3phase/multichannel/reverse)
      • Peak 270 A (1phase) / 90A (3phase/multichannel/reverse)
    • Output power:
      • Per Phase: 5 kVA
      • Max. Power: 15 kVA (1phase/3phase/multichannel) - 10kVA (reverse phase)
  • Voltage setting:
    • Range: 0-350 V (1phase/3phase/multichannel) / 0-700 V (reverse )
    • Resolution: 0.01 V
    • Accuracy: 0.1%+0.1% F.S. (16 Hz-500 Hz) / 0.1%+0.2% F.S./kHz (500 Hz-2.4 kHz)
  • Current setting:
    • Range: RMS - 90 A (1phase)/ 30A (3phase/multichannel/reverse)
    • Resolution: 0.01 A
    • Accuracy: 0.3%+0.3% F.S. (16 Hz-500 Hz) / 0.3%+0.6% F.S./kHz (500 Hz-2.4 kHz)
  • Frequency:
    • Set range: 16-2.4 kHz
    • Set resolution: 0.01 Hz
    • Set accuracy: 0.01% (16-500 Hz) / 0.1% (500-2.4 kHz)
    • Harmonic waveform: 50/60 Hz and up to 50 orders
  • DC output:
    • Voltage setting
      • Range: -495 to +495 Vdc (1phase/multichannel) / -990 to +990 Vdc (reverse)
      • Resolution: 0.01 V
      • Accuracy: <0.1%+0.1% F.S.
    • Current setting
      • Range: -30 to +30 Adc (multichannel/reverse) / -90 to +90 Adc (1phase)
      • Resolution: 0.01 A
      • Accuracy: <0.3%+0.3% F.S.
Description
Additional Informations
Reviews
Query on the Item
Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha
Description
Reviews
Query on the Item

ITECH IT7800 series of programmable AC/DC power supply, with power up to 15 kVA per 3U hight, voltage ranges up to 350 V L-N and 500 V L-N. Users are able to increase output power up to 960 kVA by configuring master-slave parallel. With intuitive LCD touch panel interface, users can be quickly familiar with the unit operation.

IT7800 series is built-in power meter and arbitrary waveform generator, which is able to simulate harmonics and other arbitrary waveform output. Users can choose single phase, three-phase, phase reversal, and multi-channel totally 4 output modes, with programmable output, and complete measurements, ITECH IT7800 series is designed for new energy, power electronics, research institutes etc.

Additional features:

  • Multi-channel function, single unit can connect/test up to 3 DUTs
  • Choose single phase, three-phase, reverse phase output mode, to simulate 3-phase imbalance, 3-phase harmonics imbalance, split phase test, reverse phase sequence tests etc.
  • Comprehensive harmonics measurement and analysis, up to 50th
  • Intuitive touch screen interface
  • Simulate arbitrary waveform output, support csv. file import
  • Standard waveforms build in
  • List mode simulates the power supply reproduction function to realize the simulation function of
  • instantaneous power interruption
  • Trigger input and output signals. 
  • Output 0-360 ° start/stop phase angle can be set
  • Surge/Sag function
  • Output relay function

Key Specifications (15 kVA model):

  • AC output:
    • Output voltage:
      • Line to Neutral: 350 Volt
      • Line to Line: 606 Volt
    • Output current:
      • RMS: 90 A (1phase) / 30A (3phase/multichannel/reverse)
      • Peak 270 A (1phase) / 90A (3phase/multichannel/reverse)
    • Output power:
      • Per Phase: 5 kVA
      • Max. Power: 15 kVA (1phase/3phase/multichannel) - 10kVA (reverse phase)
  • Voltage setting:
    • Range: 0-350 V (1phase/3phase/multichannel) / 0-700 V (reverse )
    • Resolution: 0.01 V
    • Accuracy: 0.1%+0.1% F.S. (16 Hz-500 Hz) / 0.1%+0.2% F.S./kHz (500 Hz-2.4 kHz)
  • Current setting:
    • Range: RMS - 90 A (1phase)/ 30A (3phase/multichannel/reverse)
    • Resolution: 0.01 A
    • Accuracy: 0.3%+0.3% F.S. (16 Hz-500 Hz) / 0.3%+0.6% F.S./kHz (500 Hz-2.4 kHz)
  • Frequency:
    • Set range: 16-2.4 kHz
    • Set resolution: 0.01 Hz
    • Set accuracy: 0.01% (16-500 Hz) / 0.1% (500-2.4 kHz)
    • Harmonic waveform: 50/60 Hz and up to 50 orders
  • DC output:
    • Voltage setting
      • Range: -495 to +495 Vdc (1phase/multichannel) / -990 to +990 Vdc (reverse)
      • Resolution: 0.01 V
      • Accuracy: <0.1%+0.1% F.S.
    • Current setting
      • Range: -30 to +30 Adc (multichannel/reverse) / -90 to +90 Adc (1phase)
      • Resolution: 0.01 A
      • Accuracy: <0.3%+0.3% F.S.
Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha